Hot Sale Infant Baby Incubator

Model NO.: Baby Care 7G
Model Name: Infant Incubator
Controlled by Micro-Compute Display: 8" Big LCD Display Screen
Humidity Display Range: 0%Rh~99%Rh
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc)
Perating Temperature Range: 20oc~30oc
Trademark: Poweam
Transport Package: Wooden Case
Specification: 100-8000g
Origin: China
HS Code: 90189090
Model NO.: Baby Care 7G
Model Name: Infant Incubator
Controlled by Micro-Compute Display: 8" Big LCD Display Screen
Humidity Display Range: 0%Rh~99%Rh
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc)
Perating Temperature Range: 20oc~30oc
Trademark: Poweam
Transport Package: Wooden Case
Specification: 100-8000g
Origin: China
HS Code: 90189090
Hot sale infant baby incubator (Baby Care 7G) 

Two control modes: Air mode and baby mode controlled by micro-computer
The information can be stored, consulted and indicated by the LCD display screen
Humidity and oxygen concentration display and servo control
>37C temperature set function
The air circle with outlet in both front and back
Brushless DC motor with low noise
Double wall hood, air circulation system in the way of air outlet from front and back
X-ray cassette under the bassinet
Integrated water reservoir in the shape of drawer which can be autoclaved
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Failure alarm indication
RS-232 connector
Disposable skin temperature sensor is optional

Below is tech spec:

Power supply
AC220V-230V/50Hz or AC110V-120V/50-60Hz
Max. Power output 1300VA
Mode of control Air mode and baby mode controlled by micro-computer
Air temperature control range 25ºC-37ºC (over mode 37-39ºC)
Baby temperature control range 34ºC-37ºC (over mode 37-38ºC)
Accuracy of skin temperature sensor +-0.2ºC
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition) <=0.5ºC
Temperature uniformity <=0.8ºC (mattress is on the horizontal position)
Inclination of the bassinet +-12
Noise inside hood <=45dB(A)
Failure alarm over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on
Humidity display range 0%RH~99%RH
Humidity control range 0%RH~90%RH
Accuracy of humidity +-10%RH
Indication range of oxygen concentration 0%~99%
Control range of oxygen concentration 20%~60%
Control Accuracy of oxygen concentration +-4%
Range of weight 100-8000g
Resolution for weight indication 1g
Accuracy of weight +-1%
Operating temperature range 20ºC~30ºC
Ambient air movement rate <0.3m/s
Standard Configuration Main body (including baby compartment, base, controller, I.V. POLE AND TRAY), the sensor box, skin temperature sensor and vertical height adjustment stand(VHA stand)
Optional Configuration Weighing system and monitor shelf, Disposable skin temperature sensor
Hospital 8
Hospital 8
Hospital 8
Hospital 8 Hot sale infant baby incubator (Baby Care 7G) 

Two control modes: Air mode and baby mode controlled by micro-computer
The information can be stored, consulted and indicated by the LCD display screen
Humidity and oxygen concentration display and servo control
>37C temperature set function
The air circle with outlet in both front and back
Brushless DC motor with low noise
Double wall hood, air circulation system in the way of air outlet from front and back
X-ray cassette under the bassinet
Integrated water reservoir in the shape of drawer which can be autoclaved
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Failure alarm indication
RS-232 connector
Disposable skin temperature sensor is optional

Below is tech spec:

Power supply
AC220V-230V/50Hz or AC110V-120V/50-60Hz
Max. Power output 1300VA
Mode of control Air mode and baby mode controlled by micro-computer
Air temperature control range 25ºC-37ºC (over mode 37-39ºC)
Baby temperature control range 34ºC-37ºC (over mode 37-38ºC)
Accuracy of skin temperature sensor +-0.2ºC
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition) <=0.5ºC
Temperature uniformity <=0.8ºC (mattress is on the horizontal position)
Inclination of the bassinet +-12
Noise inside hood <=45dB(A)
Failure alarm over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on
Humidity display range 0%RH~99%RH
Humidity control range 0%RH~90%RH
Accuracy of humidity +-10%RH
Indication range of oxygen concentration 0%~99%
Control range of oxygen concentration 20%~60%
Control Accuracy of oxygen concentration +-4%
Range of weight 100-8000g
Resolution for weight indication 1g
Accuracy of weight +-1%
Operating temperature range 20ºC~30ºC
Ambient air movement rate <0.3m/s
Standard Configuration Main body (including baby compartment, base, controller, I.V. POLE AND TRAY), the sensor box, skin temperature sensor and vertical height adjustment stand(VHA stand)
Optional Configuration Weighing system and monitor shelf, Disposable skin temperature sensor
Hospital 8
Hospital 8
Hospital 8
Hospital 8

Upper Limb Locking Plate

Upper limb locking plate system consists of ulna radius locking plates,humerus locking plates,clavicle locking plates,scapula locking plates,locking screw and cortical screw.

The locking plate also has locking or non-locking screw holes for different trauma screws.In the internal fixation of the upper limb, four locking screws are generally used, which are mainly divided into 2.7mm and 3.5mm diameter.

olecranon plate,humerus fracture,volar distal radius plate,clavicle fracture

Jiangsu Aomed Ortho Medical Technology Co.,Ltd , https://www.aomedortho.com

Posted on