Model NO.: Baby Care 7G
Model Name: Infant Incubator
Controlled by Micro-Compute Display: 8" Big LCD Display Screen
Humidity Display Range: 0%Rh~99%Rh
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc)
Perating Temperature Range: 20oc~30oc
Trademark: Poweam
Transport Package: Wooden Case
Specification: 100-8000g
Origin: China
HS Code: 90189090
Model NO.: Baby Care 7G
Model Name: Infant Incubator
Controlled by Micro-Compute Display: 8" Big LCD Display Screen
Humidity Display Range: 0%Rh~99%Rh
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc)
Perating Temperature Range: 20oc~30oc
Trademark: Poweam
Transport Package: Wooden Case
Specification: 100-8000g
Origin: China
HS Code: 90189090
Hot sale infant baby incubator (Baby Care 7G)Â Two control modes: Air mode and baby mode controlled by micro-computer
The information can be stored, consulted and indicated by the LCD display screen
Humidity and oxygen concentration display and servo control
>37C temperature set function
The air circle with outlet in both front and back
Brushless DC motor with low noise
Double wall hood, air circulation system in the way of air outlet from front and back
X-ray cassette under the bassinet
Integrated water reservoir in the shape of drawer which can be autoclaved
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Failure alarm indication
RS-232 connector
Disposable skin temperature sensor is optional
Below is tech spec:
Power supply |
AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Max. Power output | 1300VA |
Mode of control | Air mode and baby mode controlled by micro-computer |
Air temperature control range | 25ºC-37ºC (over mode 37-39ºC) |
Baby temperature control range | 34ºC-37ºC (over mode 37-38ºC) |
Accuracy of skin temperature sensor | +-0.2ºC |
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition) | <=0.5ºC |
Temperature uniformity | <=0.8ºC (mattress is on the horizontal position) |
Inclination of the bassinet | +-12 |
Noise inside hood | <=45dB(A) |
Failure alarm | over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on |
Humidity display range | 0%RH~99%RH |
Humidity control range | 0%RH~90%RH |
Accuracy of humidity | +-10%RH |
Indication range of oxygen concentration | 0%~99% |
Control range of oxygen concentration | 20%~60% |
Control Accuracy of oxygen concentration | +-4% |
Range of weight | 100-8000g |
Resolution for weight indication | 1g |
Accuracy of weight | +-1% |
Operating temperature range | 20ºC~30ºC |
Ambient air movement rate | <0.3m/s |
Standard Configuration | Main body (including baby compartment, base, controller, I.V. POLE AND TRAY), the sensor box, skin temperature sensor and vertical height adjustment stand(VHA stand) |
Optional Configuration | Weighing system and monitor shelf, Disposable skin temperature sensor |




Two control modes: Air mode and baby mode controlled by micro-computer
The information can be stored, consulted and indicated by the LCD display screen
Humidity and oxygen concentration display and servo control
>37C temperature set function
The air circle with outlet in both front and back
Brushless DC motor with low noise
Double wall hood, air circulation system in the way of air outlet from front and back
X-ray cassette under the bassinet
Integrated water reservoir in the shape of drawer which can be autoclaved
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Failure alarm indication
RS-232 connector
Disposable skin temperature sensor is optional
Below is tech spec:
Power supply |
AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Max. Power output | 1300VA |
Mode of control | Air mode and baby mode controlled by micro-computer |
Air temperature control range | 25ºC-37ºC (over mode 37-39ºC) |
Baby temperature control range | 34ºC-37ºC (over mode 37-38ºC) |
Accuracy of skin temperature sensor | +-0.2ºC |
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition) | <=0.5ºC |
Temperature uniformity | <=0.8ºC (mattress is on the horizontal position) |
Inclination of the bassinet | +-12 |
Noise inside hood | <=45dB(A) |
Failure alarm | over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on |
Humidity display range | 0%RH~99%RH |
Humidity control range | 0%RH~90%RH |
Accuracy of humidity | +-10%RH |
Indication range of oxygen concentration | 0%~99% |
Control range of oxygen concentration | 20%~60% |
Control Accuracy of oxygen concentration | +-4% |
Range of weight | 100-8000g |
Resolution for weight indication | 1g |
Accuracy of weight | +-1% |
Operating temperature range | 20ºC~30ºC |
Ambient air movement rate | <0.3m/s |
Standard Configuration | Main body (including baby compartment, base, controller, I.V. POLE AND TRAY), the sensor box, skin temperature sensor and vertical height adjustment stand(VHA stand) |
Optional Configuration | Weighing system and monitor shelf, Disposable skin temperature sensor |




Upper limb locking plate system consists of ulna radius locking plates,humerus locking plates,clavicle locking plates,scapula locking plates,locking screw and cortical screw.
The locking plate also has locking or non-locking screw holes for different trauma screws.In the internal fixation of the upper limb, four locking screws are generally used, which are mainly divided into 2.7mm and 3.5mm diameter.
olecranon plate,humerus fracture,volar distal radius plate,clavicle fracture
Jiangsu Aomed Ortho Medical Technology Co.,Ltd , https://www.aomedortho.com