How to operate the water bath type sterilization pot correctly?

The correct operation steps of the water bath type sterilization pot :
1. The operator who uses the water bath type sterilizing pot should pass the training test and should strictly abide by the safety operation rules and post responsibility system; if abnormal phenomena are found, they should be dealt with in time. The water bath type sterilizing pot should be inspected regularly, and at least once every six months, the external inspection should be carried out at least once a year. The preparations and inspection items before the inspection are carried out in accordance with the “Procedures” and relevant regulations, and the inspection reports are filed and filed.
2. This water bath type sterilization pot is strictly prohibited to run beyond the design pressure and temperature.
3, water bath type sterilization pot is equipped with pressure gauges, thermometers, safety valves and other accessories, to be sensitive, reliable, safe and complete. Maintenance and periodic verification should be added during use. The safety valve starting pressure of the water bath type sterilization pot is equal to the design pressure, and should be sensitive and reliable, and should be prevented from being adjusted at will. The accuracy of the pressure gauge and thermometer are all 1.5, and the difference within the tolerance is normal. The lead-free seal pressure gauge shall not be used, the pressure gauge indicates failure, the scale is unclear, the dial is broken, the pointer does not return to zero after the pressure is released, and the seal seal damage shall be replaced immediately. The thermometer should be inspected regularly. It should be calibrated with a standard thermometer before use. It should be verified once a year. If the mercury column breaks and the difference from the standard temperature exceeds 0.5 °C, it should be repaired or replaced.
4. The operator who uses the water bath type sterilization pot should pass the training and examination, and should strictly abide by the safety operation rules and post responsibility system; if abnormal phenomena are found, they should be dealt with in time.
5. When deactivated, the inner and outer surfaces of the water bath type sterilizer and lid should be cleaned. The exposed surface brush is anti-rust paint, and the safety inspection control instrument is protected by a cover.
6. If the sealing ring on the flange surface of the water bath type sterilization pot body is aging, if the wear and the defect are too large, it should be replaced in time to ensure the seal and prevent leakage.
7. During the use process, grease and oil should be applied to the sliding and rolling contact parts of the inclined self-locking wedges, pot ears, rollers, swivel flanges, etc. to ensure that the friction surface is in a lubrication state.