Model NO.: PA-900B
Anesthesia: Closed Circuit
Medical Device Regulatory Type: Type 3
Ventilation Mode: A/C, Sippv, Ippv, Simv, Psimv, P
Tidal Volume: 20-1500ml
Respiratory Rate: 1-99bpm
(I:E) Ratio: 4:1-1:4
Peep: 0-10CMH2o
Trigger Sensitivity: -10-10CMH2o
Trademark: PA
Transport Package: Cartons for Export
Specification: 0.55 CBM; 77 GS
Origin: China
HS Code: 9019200000
Hospital Medical Ventilator (PA-900B)



Common Features
Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
Pneumatically driven electrically controlled ventilator, can be used for emergency clinical resuscitation and respiratory therapy
Display: Built-in 10.4 inch color TFT fully adjustable display, able-display Pressure-Time, Frequency-Time, Pressure-Volume, Frequency-Volume and any two waveforms simultaneously on screen
Trigger Types: Pressure trigger, Flow trigger
Sigh: Ability to insert 1-8 sigh breaths in every 100 breaths, ventilation should be no less than 1.5 the tidal volume
Features built-in dual electronic flow sensors and dual respiratory modules
Power Failure Support Functions: Automatically converts-standby mode during AC power outages
Monitor Parameters: tidal volume, respiration rate, airway pressure, I:E ratio, inspiratory & expiratory status, inspiratory trigger and Others
Equipped with infrared turbine flow sensor; precisely measures gas flows, stable and reliable
9 Level adjustable humidifier
Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an automatic self-calibrating sensor
Alarms: Audible and/or visual alarms for ventilation volume, tidal volume, oxygen concentration, asphyxia, airway pressure, intubation disconnection, low oxygen, power failure and other alarms, also features a alarm history query function
Â
Advanced Model Exclusive Features
Equipped with professional medical grade air compressor tailored for long clinical times and low noise requirements
Â
Air Compressor
Air Compressor: 220V AC±10%, 50±1Hz, 700VA, also features good protective grounding against electrical activity
Output Gas Pressure: 0.4MPa±20%
Continuous output gas flow greater than or equal to 20L/min
Instantaneous output gas flow great than equal to 60L/min
Â
Specifications
Model | 900B (Standard Model) | 900B (Advanced Model) |
Display | 10.4 inch high visibility color TFT display | |
Ventilation Mode | A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT MANUAL | |
Minute Volume | Greater than or equal to 18L | |
Back-up Power Supply | At least 4 hours | |
Tidal Volume | Adjustable range: 20-1500ml, Display range: 0-2000ml | |
Respiratory Rate | 1-99bpm | |
Inspiratory/expiratory (I:E) ratio | 4:1-1:4 | |
PEEP | 0-10cmH2OÂ | |
SIMV Rate | 1-20bpm | |
Inspiratory Pressure Trigger | .-10-10cmH2OÂ | |
Trigger Sensitivity (flow) | 1-10L/m | |
Inspiratory Plateau | Adjustable from 0-50% of inspiratory time | |
Adjustable Oxygen Concentration | 45-100% | 21-100% |
Gas Supply Requirement | 280~600 kPa medical grade oxygen and compressed air supply | |
Pressure Limit | 1.0kPa~6.0kPa | |
Maximum Safe Operating Pressure | ≤6.0kPa | |
Tidal Volume Alarm | Upper Limit: 10~2000ml, Lower Limit: 0~1800ml | |
Airway Pressure Alarm | Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa | |
Oxygen Concentration Alarm | Upper Limit: 22~100%, Lower Limit: 21~80% |




Â
Nucleic Acid Extraction Reagent Kit
Nucleic Acid Extraction Reagent Kit is designed for the optimal automated extraction of total nucleic acid (RNA) from nasal/throat samples.
Nucleic acid extraction is a critical step in infectious disease testing. Nucleic acid-based detection of viral pathogens requires the extraction of RNA allowing simultaneous detection of any viral infection.
nucleic acid isolating reagent kit,DNA extraction reagent,RNA isolating reagent,nucleic acid isolating reagent,RNA purification reagent
Shenzhen Uni-medica Technology Co.,Ltd , https://www.nbunimed-global.com