Rat glycated hemoglobin A1c (GHbA1c) enzyme-linked immunosorbent assay (ELISA) kit instruction manual
This reagent is for research use only
OBJECTIVE: This kit is used to determine the content of glycated hemoglobin A1c (GHbA1c) in serum, plasma and related fluid samples of rats.
Experimental principle:
The kit uses a double antibody sandwich method to determine the level of rat glycated hemoglobin A1c (GHbA1c) in the specimen. The microplate was coated with purified rat glycosylated hemoglobin A1c (GHbA1c) antibody to prepare a solid phase antibody, and glycosylated hemoglobin A1c (GHbA1c) was sequentially added to the microcapsules of the coated mAb, followed by HRP-labeled glycated hemoglobin A1c ( The GHbA1c) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex, which is thoroughly washed and then added to the substrate TMB for color development. TMB is converted to blue under the catalysis of HRP enzyme and converted to the final yellow color by the action of an acid. The color depth is positively correlated with glycated hemoglobin A1c (GHbA1c) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of rat glycated hemoglobin A1c (GHbA1c) in the sample was calculated from a standard curve.
Kit composition:
Kit composition | 48 hole configuration | 96-well configuration | save |
Instruction manual | 1 copy | 1 copy | |
Sealing film | 2 pieces (48) | 2 pieces (96) | |
sealed bag | 1 | 1 | |
Enzyme label coated plate | 1×48 | 1×96 | Store at 2-8 ° C |
Standard: 3600 nmol/L | 0.5ml × 1 bottle | 0.5ml × 1 bottle | Store at 2-8 ° C |
Standard dilution | 1.5ml × 1 bottle | 1.5ml × 1 bottle | Store at 2-8 ° C |
Enzyme standard reagent | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Sample diluent | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Developer A solution | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Developer B solution | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Stop solution | 3ml × 1 bottle | 6ml × 1 bottle | Store at 2-8 ° C |
Concentrated washing solution | (20ml × 20 times) × 1 bottle | (20ml × 30 times) × 1 bottle | Store at 2-8 ° C |
Sample processing and requirements:
1. Serum: The blood is naturally coagulated for 10-20 minutes at room temperature and centrifuged for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if precipitation occurs during storage, it should be centrifuged again.
2. Plasma: EDTA or sodium citrate should be selected as an anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again.
3. Urine: Collect with a sterile tube and centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. The chest and ascites and cerebrospinal fluid are referred to.
4. Cell culture supernatant: When detecting secreted components, collect them in a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When the components in the cells were detected, the cell suspension was diluted with PBS (pH 7.2-7.4), and the cell concentration reached about 1 million/ml. By repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
5. Tissue specimen: After cutting the specimen, weigh the weight. Add a certain amount of PBS, pH 7.4. It was quickly frozen and stored in liquid nitrogen for use. The specimen still maintains a temperature of 2-8 ° C after melting. A certain amount of PBS (pH 7.4) was added, and the specimen was homogenized by hand or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. One part of the package is to be tested, and the rest is frozen for use.
6. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 °C, but repeated freezing and thawing should be avoided.
7. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Steps
- Dilution and loading of standard products: 10 wells of standard wells are placed on the enzyme-labeled plate, 100 μl of standard is added to the first and second wells, and standard dilutions are added to the first and second wells. 50μl, mix; then add 100μl from the first hole and the second hole to the third hole and the fourth hole respectively, and then add 50μl of the standard dilution solution in the third and fourth holes, and mix; Take 50 μl of each of the third and fourth wells, discard them, add 50 μl to each of the fifth and sixth wells, and add 50 μl of the standard dilution solution to the fifth and sixth wells, mix and mix; Then, 50 μl of each of the fifth and sixth holes are respectively added to the seventh and eighth holes, and then 50 μl of the standard dilution solution is added to the seventh and eighth holes, respectively, and the seventh and eighth holes are mixed after mixing. 50 μl of each was added to the ninth and tenth holes, and 50 μl of the standard dilution was added to the ninth and tenth holes, respectively, and 50 μl of each of the ninth and tenth holes was discarded. (The amount of each well was 50 μl after dilution, and the concentrations were 2400 nmol/L, 1600 nmol/L, 800 nmol/L, 400 nmol/L, 200 nmol/L).
- Adding samples: Set blank holes separately (the blank control holes are not added with the sample and the enzyme standard reagent, the other steps are the same), and the sample holes to be tested. Add 40 μl of the sample dilution to the sample well to be tested on the enzyme-labeled plate, and then add 10 μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, and shake gently to mix.
- Incubation: The plate was sealed with a sealing film and incubated at 37 ° C for 30 minutes.
- Solution: 20 times concentrated washing solution was diluted 20 times with distilled water and used.
- Washing: Carefully remove the sealing film, discard the liquid, dry it, fill each well with the washing solution, let stand for 30 seconds, then discard it, repeat 5 times, and pat dry.
- Add enzyme: 50 μl of enzyme labeling reagent was added to each well, except for blank wells.
- Incubation: The operation is the same as 3.
- Washing: The operation is the same as 5.
- Color development: Add 50 μl of color developer A to each well, then add 50 μl of color developer B, gently shake and mix, and develop color at 37 ° C for 15 minutes.
- Termination: 50 μl of stop solution was added to each well to terminate the reaction (in this case, the blue color turned yellow).
- Measurement: The absorbance (OD value) of each well was measured sequentially with a blank air conditioner of zero and a wavelength of 450 nm. The measurement should be carried out within 15 minutes after the addition of the stop solution.
Precautions:
- The kit should be taken out from the refrigerated environment and should be used at room temperature for 15-30 minutes before use. If the enzyme label is unsealed after opening, the slats should be stored in a sealed bag.
- Concentrated washing liquid may crystallize out. When diluted, it can be heated and dissolved in a water bath. The washing will not affect the result.
- The sampler should be used for each step, and the accuracy should be corrected frequently to avoid test errors. It is best to control the loading time within 5 minutes. If the number of specimens is large, it is recommended to use a gun.
- Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is larger than the OD value of the first hole of the standard well), please first dilute the sample dilution with a certain multiple (n times) and then measure it. When calculating, multiply the total dilution by the total dilution. Multiple (×n×5).
- The sealing film is intended for single use only to avoid cross-contamination.
- Please keep the substrate away from light.
- Strictly follow the instructions of the manual, the test results must be based on the microplate reader reading.
- All samples, washings and various wastes should be treated as infectious materials.
- The different batch components of this reagent must not be mixed.
10. In the case of an English manual, the English manual shall prevail.
Calculation:
Taking the concentration of the standard as the abscissa and the OD as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; multiply by the dilution factor; or use the concentration of the standard Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply by the dilution factor, which is the actual concentration of the sample.
Kit performance:
1. The linear regression coefficient of the sample and the expected concentration correlation coefficient R value is 0.92 or more.
2. Within and within the batch should be less than 9% and 15% respectively
examination range:
100 nmol/L -3000 nmol/L
Storage conditions and expiration date:
1. Kit storage: 2-8 ° C
2. Validity: 6 months
Cosmetic ingredients are too broad a range. Our industry is usually divided into: 1. Basic ingredients, water or oil The main basic ingredients of general skin care products are distilled water or purified water, oil is vegetable oil or animal oil or mineral oil, according to the form of oil: liquid oil, semi-solid fat, solid wax. 2. Added ingredients, functional ingredients or control and adjustment ingredients Functional ingredients are mainly moisturizing, whitening, anti-aging, acne and other effective ingredients, according to different processes, plants as extracts, other organisms as extracts. Control components are preservatives, antibacterial agents, thickeners, emulsifiers, flavors, pigments and so on. Preservatives ensure that the product will not rot and deteriorate, antibacterial agents ensure that the product will not be infected by fungi, thickener to adjust the viscosity and flow variation, emulsifier to determine the product evenly dispersed into another substance, essence and pigment to ensure the stability of product smell and color. So, I don't know if that's what you want to know? Or do you want to know the names, the structures, the properties of the various monomer components, and if you want to know about that you can go to the INCI directory and Cos Dna for details